Generators Wiring Chart

MODEL WIRE SIZE PHASE VOLT AMP BREAKER SIZE KW *MAX CU. FT.
AK4 10-2 + G 1 240 16.7 25 4.0 75
208 14.4 20 3.0 50
AK5 10-2 + G 1 240 20.8 30 5.0 100
208 18.0 25 3.7 60
AK6 8-2 + G 1 240 25.0 35 6.0 160
208 21.6 30 4.5 85
AK7 8-2 + G 1 240 29.2 40 7.0 220
208 25.2 35 5.2 110
AK8.5 6-2 + G 1 240 35.4 50 8.5 300
208 30.7 45 6.4 190
AK10 6-2 + G 1 240 41.7 60 10.0 400
208 36.1 50 7.5 250
AK12 6-2/10-2 + G **1 240 33.3/16.7 50/25 12.0 500
AK14 6-2/10-2 + G **1 240 37.5/20.8 50/30 14.0 600
AK17

For electrical specifications
please call the factory at 1-800-331-0349 

725
AK20 900
AK30 1350
3K8 10-3 + G 3 208 21.9 30 7.9 300
3K10 8-3 + G 3 208 28.1 35 10.1 400
3K12 8-3 + G 3 208 31.3 40 11.3 500
3K14 6-3 + G 3 208 40.2 50 14.5 600
3K20

For electrical specifications
please call the factory at 1-800-331-0349 

800
3K24 1000
3K28 1200
3K36 1500

Steamer Dimensions:
AK4-AK10 6-1/4"W x 13"H x 16-1/2"L
AK12,AK14 and 3K Models 6-1/4"W x 14"H x 16-1/2"L

Shipping:

AK4-AK10 7-1/4"W x 20-1/2"H x 23"L, Weight 32 lbs.
AK12,AK14 and 3K Models 7-1/4"W x 20-1/2"H x 23"L, Weight 32 lbs.

*IMPORTANT: The maximum cubic footage is for reference only. Complex room construction and
material variables may substantially alter the model required for your installation.
For further information see "The Steam Room Construction and Generator Sizing Guide".
Manufactures of room construction materials should be consulted for approval of material use in
a steam room environment.

*SEE GENERATOR INSTALLATION INSTRUCTIONS FOR SAFETY WARNINGS.
**NOTE:
Single phase AK12 and AK14 steamers require two separate line feed circuits.
 

NOTICE: SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.